The Product

The Product

Reducing Skin Stress and Strain

The traditional rectangular design of skin closure systems lend themselves to stress between the highly elastic skin and the rigid polyester mesh. Straight lines can cause friction to occur where stress points are located, and are typically in the four corners.

We have redesigned the shape of the mesh to introduce curved ends. This reduces the area that is under stress and dissipates the fiction and force across the entirety of the material.

Competitor Mesh Under Stress

Curved Mesh Under Stress

Substantial Reduction in Skin Stress3

Strain = 33.3% (Model Length 152.44mm)

Competitor exofin fusion® REDUCTION (%)
High Stress Area (mm2) 1258 417 66.8%
Max Stress (psi) 933 730 21.8%
Total Force (lbf) 1913 1095 42.8%

3 Content provided by D&D Innovative Research (DDIR) LLC, 7/29/2019.

Competitor Mesh Under Stress


New Curved Mesh Under Stress


Substantial Reduction in Skin Stress3

Strain = 33.3% (Model Length 152.44mm)

Competitor exofin fusion® REDUCTION (%)
High Stress Area (mm2) 1258 417 66.8%
Max Stress (psi) 933 730 21.8%
Total Force (lbf) 1913 1095 42.8%

3 Content provided by D&D Innovative Research (DDIR) LLC, 7/29/2019.

Less Exposure to Patient is a Good Thing

The mesh no longer contains an initiator.  Instead the initiator is delivered with the polymerizable adhesive.  This method ensures the user of a consistent and fast polymerization time.  Average “dry times” are less than 45 seconds.

Since the initiator will now be delivered with the adhesive, the patient will experience less exposure to the initiation chemical directly on the skin.  Extracted samples showed a 61% REDUCTION in the amount of initiator that the patient could be exposed to.

Keeping Mesh on the Skin

The new mesh pattern has larger openings which allow more adhesive to flow through the mesh and on to the patient’s skin. The more open design will allow the adhesive to create a stronger bond on the skin and keep the mesh secure and in place for the desired amount of time.

Unlike the competition, the exofin fusion® adhesive will polymerize (dry) on the patient’s skin even if it is not directly on the mesh.  This eliminates the need to clean up the wet adhesive that tends to get on the surrounding area during application

Lastly, measured amounts of adhesive have been added to the kit providing just the right amount of adhesive for each size of mesh.

For More Information

For more information about exofin fusion® skin closure system, call
your Chemence Medical, Inc. Customer Support Representative at

+1 844-MED-GLUE (844-633-4583).

To discuss placing an order:

For More Information

To receive more information or
to discuss placing an exofin fusion® order,
contact your Chemence Medical, Inc.
Customer Support Representative
at +1 844-633-4583.